Search results

Search for "static mixer" in Full Text gives 11 result(s) in Beilstein Journal of Organic Chemistry.

Honeycomb reactor: a promising device for streamlining aerobic oxidation under continuous-flow conditions

  • Masahiro Hosoya,
  • Yusuke Saito and
  • Yousuke Horiuchi

Beilstein J. Org. Chem. 2023, 19, 752–763, doi:10.3762/bjoc.19.55

Graphical Abstract
  • [23] or a static mixer [24]. Slug-flow is a simple method for passive mixing, but the formation of slug-flow depends on the tube diameter [23], and the reaction rate decreases as the tube diameter increases [25][26]. The gas–liquid biphasic reaction also displays the same characteristic, and a static
  • mixer needs to be developed to enable more robust aerobic oxidation under continuous-flow conditions. A static mixer is generally used by inserting it into a tube reactor. In the gas-liquid biphasic flow reaction, the static mixer has to be inserted into the full range of the tube reactor to maintain
  • the reactor. As the gas–liquid reaction mixture passes through the honeycomb reactor, the porous material functions as a static mixer, maintaining high mixing efficiency throughout the aerobic oxidation process. We believe that this processing technology offers much potential for application as a flow
PDF
Album
Supp Info
Full Research Paper
Published 31 May 2023

Heterogeneous metallaphotoredox catalysis in a continuous-flow packed-bed reactor

  • Wei-Hsin Hsu,
  • Susanne Reischauer,
  • Peter H. Seeberger,
  • Bartholomäus Pieber and
  • Dario Cambié

Beilstein J. Org. Chem. 2022, 18, 1123–1130, doi:10.3762/bjoc.18.115

Graphical Abstract
  • the packed bed could cause the relatively long time necessary to reach steady-state conditions. Consequently, we evaluated a static mixer to improve the flow distribution in the packed bed [40][41][42]. The residence time distribution (RTD) of the reactor was measured via a pulsed tracer experiment
  • (see Supporting Information File 2 for details) and compared with a modified reactor unit containing a helical static mixer (Figure 6) [43]. The addition of the static mixer had a limited impact on both the standard deviation of the mean residence time and the reaction outcome, most likely due to the
  • 15 hours, comparable with batch results (22 h). The production campaign of 1 for a seven day experiment. Photo of the packed column with a helical static mixer (polished SS316, 10 cm length, 15 mixing elements L/D = 1.04 from Stamixco AG). C–O coupling between 4-iodobenzotrifluoride and N-(Boc
PDF
Album
Supp Info
Full Research Paper
Published 29 Aug 2022

Inductive heating and flow chemistry – a perfect synergy of emerging enabling technologies

  • Conrad Kuhwald,
  • Sibel Türkhan and
  • Andreas Kirschning

Beilstein J. Org. Chem. 2022, 18, 688–706, doi:10.3762/bjoc.18.70

Graphical Abstract
  • comparable to microwave-induced heating. In continuation of these studies a two-step sequence was developed which showed that Claisen rearrangements can be accelerated in water as solvent (Scheme 8B) [51]. The phenolate salt 11 was mixed with allyl bromide in a static mixer and inductively heated to 110 °C
PDF
Album
Review
Published 20 Jun 2022

A comprehensive review of flow chemistry techniques tailored to the flavours and fragrances industries

  • Guido Gambacorta,
  • James S. Sharley and
  • Ian R. Baxendale

Beilstein J. Org. Chem. 2021, 17, 1181–1312, doi:10.3762/bjoc.17.90

Graphical Abstract
PDF
Album
Review
Published 18 May 2021

Heterogeneous photocatalysis in flow chemical reactors

  • Christopher G. Thomson,
  • Ai-Lan Lee and
  • Filipe Vilela

Beilstein J. Org. Chem. 2020, 16, 1495–1549, doi:10.3762/bjoc.16.125

Graphical Abstract
PDF
Album
Review
Published 26 Jun 2020

Nanangenines: drimane sesquiterpenoids as the dominant metabolite cohort of a novel Australian fungus, Aspergillus nanangensis

  • Heather J. Lacey,
  • Cameron L. M. Gilchrist,
  • Andrew Crombie,
  • John A. Kalaitzis,
  • Daniel Vuong,
  • Peter J. Rutledge,
  • Peter Turner,
  • John I. Pitt,
  • Ernest Lacey,
  • Yit-Heng Chooi and
  • Andrew M. Piggott

Beilstein J. Org. Chem. 2019, 15, 2631–2643, doi:10.3762/bjoc.15.256

Graphical Abstract
  • with static mixer, SPD-M10AVP diode array detector and SCL-10AVP system controller with standard Rheodyne injection port. The columns used in the purification of the metabolites were selected from either a Hypersil C18 column (50 × 100 mm, 5 μm; Grace Discovery), a Vydac C18 column (50 × 100 mm, 5 μm
PDF
Album
Supp Info
Full Research Paper
Published 05 Nov 2019

A general and atom-efficient continuous-flow approach to prepare amines, amides and imines via reactive N-chloramines

  • Katherine E. Jolley,
  • Michael R. Chapman and
  • A. John Blacker

Beilstein J. Org. Chem. 2018, 14, 2220–2228, doi:10.3762/bjoc.14.196

Graphical Abstract
  • fifth the volume of that in Table 1, entry 2, provides a much shorter tres than the in-line static mixer (SM) with comparable conversion of N-benzyl-N-methylamine (1) to the N-alkyl-N-chloramine 5 at steady state, representing a productivity value of 5.6 mol L−1 h−1. The same reactor geometry was used
PDF
Album
Supp Info
Full Research Paper
Published 24 Aug 2018

Assessing the possibilities of designing a unified multistep continuous flow synthesis platform

  • Mrityunjay K. Sharma,
  • Roopashri B. Acharya,
  • Chinmay A. Shukla and
  • Amol A. Kulkarni

Beilstein J. Org. Chem. 2018, 14, 1917–1936, doi:10.3762/bjoc.14.166

Graphical Abstract
  • a flow reactor tube of required length and diameter or a microchannel reactor having various geometries or a static mixer) or a continuous stirred tank reactor or a fixed bed reactor or other intensified process equipment viz. spinning disc reactor, impinging jet reactor etc.) and a thermostat which
PDF
Album
Review
Published 26 Jul 2018

Continuous formation of N-chloro-N,N-dialkylamine solutions in well-mixed meso-scale flow reactors

  • A. John Blacker and
  • Katherine E. Jolley

Beilstein J. Org. Chem. 2015, 11, 2408–2417, doi:10.3762/bjoc.11.262

Graphical Abstract
  • solutions of N,N-dialkyl-N-chloramines produced continuously will enable their use in tandem flow reactions with a range of nucleophilic substrates. Keywords: amine; biphasic; chloramine; chlorination; continuous flow chemistry; CSTR; static mixer; sodium hypochlorite; tube reactor; Introduction N
  • homopolymer, Delrin® that are solvent and oxidant resistant [34]. The set-up comprised one pump for the organic phase (amine/toluene) and one for the aqueous phase (NaOCl/water). The feeds were connected via a stainless steel T-piece to tubing (1/4 inch OD, 3/16 inch ID) containing static mixer tubes (1/8
  • inch ID, 3/16 inch OD) along the flow channel (Figure 2). The length of the reactor and number of static mixer inserts were adjusted to vary the residence time, thus maintaining sufficient flow rate to give effective mixing. Initial experiments using toluene and an aqueous dye were used to assess
PDF
Album
Supp Info
Full Research Paper
Published 02 Dec 2015

The synthesis of active pharmaceutical ingredients (APIs) using continuous flow chemistry

  • Marcus Baumann and
  • Ian R. Baxendale

Beilstein J. Org. Chem. 2015, 11, 1194–1219, doi:10.3762/bjoc.11.134

Graphical Abstract
PDF
Album
Review
Published 17 Jul 2015

Flow Giese reaction using cyanoborohydride as a radical mediator

  • Takahide Fukuyama,
  • Takuji Kawamoto,
  • Mikako Kobayashi and
  • Ilhyong Ryu

Beilstein J. Org. Chem. 2013, 9, 1791–1796, doi:10.3762/bjoc.9.208

Graphical Abstract
  • , equipped with a static mixer having 150 μm width and an automated fraction collector. Using the optimized flow conditions (70 °C, 10–15 min), high yielding conversions of 1b to 3b and 1c to 3c were also obtained. Pictures of the flow microreactor system (MiChS® System X-1), a micromixer (MiChS β-150
PDF
Album
Supp Info
Letter
Published 03 Sep 2013
Other Beilstein-Institut Open Science Activities